Having a good healthy growing environment for your plants is of paramount importance. At Esoteric Hydroponics, we can offer advice on all ventilation and environmental control requirements. Visit our shop or contact us. Good air circulation is an important factor in any growing environment. An extractor fan is required to bring fresh air from the outside, into the growroom and another extractor fan is needed to remove the stale air. On some occasions, only the one extractor might be used to extract stale air from the grow room and the fresh air is replenished through vents in doors, windows and walls.

An adequate supply of CO2 in the growing environment is probably the main reason why an extractor is a requirement. Plants will quickly use all available CO2 in an enclosed environment, which could lead to slow growth of plants. Our range of extractor fans and environmental control equipment will ensure that you get the best results everytime.

With extraction it is very easy to over do it or under do it, so it is therefore very easy to get it wrong. We operate a "suck it and see" policy where if you get it wrong you can come in and exchange the extraction / carbon filter / ducting / spigots for the right ones. You pay the difference if upgrading, we pay the difference if downgrading. This is only applicable for 2 weeks after purchase.

1
Hydroponic Systems
page 5
2
Grow Lights (HPS etc)
page 18
3
Nutrients & Additives
page 34
4
Fans & Filters         
page 44
5
Grow Media       
page 49
6
CO2 Release Systems
page 54
7
Environmental Controls
page 56
8
Bugs/Pest Control
page 63
9
Miscellaneous
page 64
10
Books/Literature  
page 66
11
Starter Kits          
page 67
12
Ordering               
page 74

44

 

 

 


[ Request a Catalogue & CD ] [ Shopping Cart / Checkout ] [ Goto Top of Page ]

 

Fans & Filters

Click for a larger view

The RVK range of fans made in Germany by LTI are quiet and powerful. They are also ideal for connecting to our range of carbon filters. The LTI extractor fans come fully recommended. If you are not sure what size extractor fan to use, it's easy to work out. Simply calculate the volume of the growing environment to the nearest cubic metre. This is done by multiplying:

Length x Width x Height = Volume of your room in cubic metres (m³) and then multiply the answer by 20.

Ideally, air needs to be replaced every three minutes (or twenty times an hour). Therefore, just multiply the volume of your growroom by 20. Measure the height, width and length of your room before contacting Esoteric Hydroponics.

For example, a room of 3 metres x 4 metres x 2.5 metres high = 30m³ and 30m³ x 20 changes per hour = 600m³ per hour. Once this has been calculated, you can select the correct fan.

Combinations of different fans can be used.

These extraction fans are second to none. They are industrial low wattage, high output fans that are designed for the job in hand. These fans can be run 24 hours, 7 days, 356 days a year without any hassle or problems. In fact, this is what they have been designed for. Don't buy cheap and end up buying twice; cheap extractors are meant to be on and off for short periods of time - these ain't.

Please contact or visit our shop if you are in any way unsure or need clarification of which size of fan to choose - it's important to get the ventilation right.

The LTI/RVK extraction motors are completely silent however, the air flow is not. If noise is a problem then stick one carbon filter on one end of the extractor and a silencer on the other end and hey presto, one noiseless extraction unit which is also odour free.

 
Tues January 06 2009  
Click for a larger view

Inline Silent RVK/LTI small
fan 100mm 4" 175m³ / hour
Code: F1 £115
Inline Silent RVK/LTI small
fan 125mm 5" 225m³ / hour
Code: F2 £125
Inline Silent RVK/LTI medium
fan 150mm 6" 420m³ / hour
Code: F3 £130
Inline Silent RVK/LTI medium
fan 160mm 6" 450m³ / hour
Code: F4 £140
Inline Silent RVK/LTI medium
super fan 160mm 6" 625m³ / hour
Code: F5 £165
Inline Silent RVK/LTI large
fan 200mm 8" 750m³ / hour
Code: F6 £205
Inline Silent RVK/LTI large
fan 250mm 10" 1000m³ / hour
Code: F8 £255
Inline Silent RVK/LTI large
fan 315mm 12.5" 1300m³ / hour
Code: F7 £300

Medium Floor Fan - 30cm (12 inch) Code: F55 £55
Large Floor Fan - 46cm (18 inch) Code: F56 £85

[ Shopping Cart / Checkout ] [ Goto Top of Page ]


 

Fans And Mountain Brackets

100mm small Mounting Bracket Code: F11 £15
125mm medium Mounting Bracket Code: F12 £15
150mm large Mounting Bracket Code: F13 £15
160mm medium Mounting Bracket Code: F14 £15
200mm large Mounting Bracket Code: F15 £15
250mm large Mounting Bracket Code: F20 £25
315mm extra large Mounting
Bracket
Code: F16 £25
Jubilee clips - fit all fans, filters and
ducting
Code: F17 £5
Hook plate Code: F18 £5
10m of hanging chain Code: F19 £25


Spigots

Spigots allow the air flow of multiple ducts to be combined into one fan. The desired effect is to draw hot air away from the air cooled lights. You require 75mm ducting from each air cooled reflector to your spigot. The spigot can be attached to the appropriate fan directly or via larger ducting.

Two way spigot manifold with
reducer 2 x 100mm inlets,
1 x 150mm outlet
Code: F23 £60
Four way spigot manifold
4 x 100mm inlets, 1 x 200mm
outlet
Code: F21 £70
Six way spigot manifold 6 x 100mm
inlets, 1 x 200mm outlet
Code: F22 £85
 


Click for a larger view

Click for a larger view

Click for a larger view


[ Shopping Cart / Checkout ] [ Goto Top of Page ]

 

 

Ducting

Click for a larger view

Silencers

Click for a larger view

 
10m of 100mm Ducting Code: F54 £30
10m of 125mm Ducting Code: F47 £30
10m of 150mm Ducting Code: F48 £35
10m of 160mm Ducting Code: F49 £35
10m of 200mm Ducting Code: F50 £45
10m of 250mm Ducting Code: F52 £55
10m of 315mm Ducting Code: F51 £75

10m of 100mm Soundproofed
Ducting
Code: F46SP £90
10m of 125mm Soundproofed
Ducting
Code: F47SP £90
10m of 150mm Soundproofed
Ducting
Code: F48SP £105
10m of 160mm Soundproofed
Ducting
Code: F49SP £105
10m of 200mm Soundproofed
Ducting
Code: F50SP £135
10m of 250mm Soundproofed
Ducting
Code: F52SP £175
10m of 315mm Soundproofed
Ducting
Code: F51SP £225

Cloth Ducting Tape Code: F30 £10

Silencers

Silencer 100mm Code: S46SP £95
Silencer 125mm Code: S47SP £120
Silencer 150mm Code: S48SP £160
Silencer 160mm Code: S49SP £170
Silencer 200mm Code: S50SP £250
Silencer 250mm Code: S51SP £295
Silencer 315mm Code: S52SP £370

[ Shopping Cart / Checkout ] [ Goto Top of Page ]

 

 

Filters

Carbon Filter 100mm - filters
unwanted odours
Code: F31 £95
Carbon Filter 125mm - filters
unwanted odours
Code: F35 £120
Carbon Filter 150mm - filters
unwanted odours
Code: F32 £160
Carbon Filter 160mm - filters
unwanted odours
Code: F36 £170
Carbon Filter 200mm - filters
unwanted odours
Code: F33 £250
Carbon Filter 250mm - filters
unwanted odours
Code: F46 £295
Carbon Filter 315mm - filters
unwanted odours
Code: F37 £370
Inline Filter 150mm - filters
unwanted odours
Code: F34 £160


Fan Filter Combos

Silent LTI Fan, 100mm, 175m³
with filter
Code: F38 £190
Silent LTI Fan, 125mm, 225m³
with filter
Code: F39 £220
Silent LTI Fan, 150mm, 420m³
with filter
Code: F40 £255
Silent LTI Fan, 160mm, 450m³
with filter
Code: F41 £275
Silent LTI Super Fan, 160mm,
625m³ with filter
Code: F42 £295
Silent LTI Fan, 200mm, 750m³
with filter
Code: F43 £355
Silent LTI Fan, 250mm, 1000m³
with filter
Code: F45 £475
Silent LTI Fan, 315mm, 1300m³
with filter
Code: F44 £580


Padded Collars

Padded collars - the professional way of fitting ducting or air cooled hoods to fans.

Padded Collar 100mm (4inch) Code: F57 £10
Padded Collar 125mm (5 inch) Code: F58 £10
Padded Collar 150mm (6 inch) Code: F59 £15
Padded Collar 160mm (6.5inch) Code: F60 £15
Padded Collar 200mm (8 inch) Code: F61 £20
Padded Collar 250mm (10 inch) Code: F62 £20
Padded Collar 315mm (12.5 inch) Code: F63 £25
 
These are the best carbon filters around. Unwanted odours can be a problem for indoor gardeners. Whether you are growing peppers, strawberries or your favourite herbs, carbon filters will remove any odours that come from your crop. Carbon filters work using activated granules of charcoal by which odours are extracted through the fans.   Click for a larger view

Installing a carbon filter is easy and takes just a few moments. Usually, the activated charcoal in your carbon filter will last for a minimum of 12 months. Carbon filters are an essential accessory if you are concerned about unwanted odours. Full instructions supplied with every carbon filter.   Click for a larger view